How to Test TDS Rejection Rate (Field Method)

Rejection rate = (feed TDS − product TDS) ÷ feed TDS × 100%. It is the single most practical field metric for RO performance — measurable in 60 seconds with a calibrated TDS pen.

Key points

Action checklist

  1. Calibrate TDS meters before the inspection (reference solution or cross-check two meters).
  2. Record feed TDS, product TDS, water temperature, and feed pressure for each sample.
  3. Flush new systems per the manual before taking acceptance readings.
  4. Compute rejection rate per unit; flag any unit far below the lot average.
  5. Photograph meter readings with unit serial numbers visible.
  6. File the readings with the inspection report for traceability.

Free one-page checklist (PDF)

Print it, bring it to the factory or the inspection. No signup needed.

Download free PDF checklist

Common questions

My product TDS is 30 ppm from 300 ppm feed. Is that good?

That is a 90% rejection rate — acceptable for many residential systems but below what a new standard membrane should deliver (typically mid-to-high 90s). Check pre-filter condition and feed pressure before blaming the membrane.

Why do two meters give different readings?

Usually calibration drift or temperature compensation differences. Always cross-check with a second meter and a reference solution before rejecting a lot over TDS numbers.

Related reading

How to QC RO Membranes Before ShipmentHow to Read an RO Spec Sheet (Without Getting Fooled)Wiki: tdsWiki: ro membrane
A note on honesty. CWS provides sourcing and QC services for water purification products. This guide is general information for overseas buyers — not a guarantee of any outcome. We don't promise the lowest price in China, and we don't promise zero defects. What we do promise: written inspection criteria, lot traceability, and telling you when something is outside what we can verify.